Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:r0lmc4p4pslnzzdt > Sampling and detect...

Sampling and detection of airborne influenza virus towards point-of-care applications [Elektronisk resurs]

Ladhani, Laila (författare)
Pardon, Gaspard (författare)
Meeuws, Hanne (författare)
van Wesenbeeck, Liesbeth (författare)
Schmidt, Kristiane (författare)
Stuyver, Lieven (författare)
van der Wijngaart, Wouter (författare)
HMEEUWS1@its.jnj.com (medarbetare)
KTH Skolan för elektro- och systemteknik (EES) (utgivare)
Publicerad: Plos One, 2017
Engelska.
Ingår i: PLoS ONE. - 1932-6203.
Läs hela texten
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Airborne transmission of the influenza virus contributes significantly to the spread of this infectious pathogen, particularly over large distances when carried by aerosol droplets with long survival times. Efficient sampling of virus-loaded aerosol in combination with a low limit of detection of the collected virus could enable rapid and early detection of airborne influenza virus at the point-of-care setting. Here, we demonstrate a successful sampling and detection of airborne influenza virus using a system specifically developed for such applications. Our system consists of a custom-made electrostatic precipitation (ESP)-based bioaerosol sampler that is coupled with downstream quantitative polymerase chain reaction (qPCR) analysis. Aerosolized viruses are sampled directly into a miniaturized collector with liquid volume of 150 μL, which constitutes a simple and direct interface with subsequent biological assays. This approach reduces sample dilution by at least one order of magnitude when compared to other liquid-based aerosol bio-samplers. Performance of our ESP-based sampler was evaluated using influenza virus-loaded sub-micron aerosols generated from both cultured and clinical samples. Despite the miniaturized collection volume, we demonstrate a collection efficiency of at least 10% and sensitive detection of a minimum of 3721 RNA copies. Furthermore, we show that an improved extraction protocol can allow viral recovery of down to 303 RNA copies and a maximum sampler collection efficiency of 47%. A device with such a performance would reduce sampling times dramatically, from a few hours with current sampling methods down to a couple of minutes with our ESP-based bioaerosol sampler. 

Ämnesord

Engineering and Technology  (hsv)
Environmental Biotechnology  (hsv)
Diagnostic Biotechnology  (hsv)
Teknik och teknologier  (hsv)
Miljöbioteknik  (hsv)
Diagnostisk bioteknologi  (hsv)
Medical Engineering  (hsv)
Medical Laboratory and Measurements Technologies  (hsv)
Medicinteknik  (hsv)
Medicinsk laboratorie- och mätteknik  (hsv)
Inställningar Hjälp

Beståndsinformation saknas

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy