Airspace Dimension Assessment for early detection of lung function impairment in the peripheral airways of firefighters [Elektronisk resurs]

Kisiel, Marta A., 1984- (författare)
Cai, Gui-Hong (författare)
Petersson Sjögren, Madeleine (författare)
Löndahl, Jakob (författare)
Jakobsson, Jonas (författare)
Wollmer, Per (författare)
Malinovschi, Andrei, 1978- (författare)
Svartengren, Magnus (författare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Publicerad: European Respiratory Society (ERS), 2023
Engelska.
Ingår i: ERJ Open Research. ; 9:2
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Introduction Firefighters have increased risk of chronic respiratory disease. Standard clinical techniques used in medical checkups may not detect the earliest microstructural changes in peripheral airways. A new technique called Airspace Dimension Assessment (AiDA) has been shown to enable early detection of emphysema in COPD. This method may be useful in the occupational setting to detect early pulmonary changes and enable prevention. The aim of the present study was to evaluate whether AiDA detects changes in the most peripheral airways of firefighters. Methods AiDA, measuring the effective airspace radius ( r AiDA ) and zero-second recovery ( R 0 ), was used as a complement to other standardised lung function measures in 21 male firefighters and 16 age-matched male controls. Results There were significant differences in r AiDA and R 0 between firefighters (mean±sd r AiDA 0.301±0.024 mm; mean±sd R 0 0.336±0.116 arbitrary units) and controls (mean±sd r AiDA 0.276±0.044 mm; mean±sd R 0 0.5760.168 arbitrary units), p=0.03 and p<0.001, respectively. Higher forced vital capacity was found in firefighters (mean 101% of predicted) than in controls (mean 93% of predicted; p=0.03). No significant differences were found with regard to either the ratio between forced expiratory volume in 1 s and forced vital capacity or forced expiratory volume in 1 s. The majority of firefighters had diffusing capacity of the lung for carbon monoxide, oscillometry and single-breath nitrogen washout values within the normal ranges. Conclusion AiDA parameters can provide information on early pulmonary peripheral changes that may not be seen with standard techniques used in screening of pulmonary function. 

Ämnesord

Medical and Health Sciences  (hsv)
Clinical Medicine  (hsv)
Respiratory Medicine and Allergy  (hsv)
Medicin och hälsovetenskap  (hsv)
Klinisk medicin  (hsv)
Lungmedicin och allergi  (hsv)
Medical and Health Sciences  (hsv)
Health Sciences  (hsv)
Occupational Health and Environmental Health  (hsv)
Medicin och hälsovetenskap  (hsv)
Hälsovetenskaper  (hsv)
Arbetsmedicin och miljömedicin  (hsv)
Lungmedicin  (uu)
Lung Medicine  (uu)
Fysiologi  (uu)
Physiology  (uu)

Genre

government publication  (marcgt)
Inställningar Hjälp

Ingår i annan publikation. Gå till titeln ERJ Open Research

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy