Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:r0lmrw94pv8p4r2c > Investigation of co...

Investigation of corrosion properties of metals for degradable implant applications [Elektronisk resurs]

Beaussant Törne, Karin, 1985- (författare)
Weissenrieder, Jonas (preses)
Mueller, Wolf-Dieter (opponent)
Surface physics (medarbetare)
KTH Skolan för teknikvetenskap (SCI) (utgivare)
ISBN 9789177295280
Publicerad: KTH Royal Institute of Technology, 2017
Engelska 80
Serie: TRITA-FYS, 0280-316X
Läs hela texten
Läs hela texten
  • E-bokAvhandling(Diss. (sammanfattning) Stockholm : Kungliga Tekniska högskolan, 2017)
Sammanfattning Ämnesord
Stäng  
  • Nedbrytbara metaller utgör en ny klass av biomaterial med potential attersätta permanenta material i tillfälliga applikationer. Detta för att minskarisken för långvariga biverkningar. I den pågående forskningen för att utvecklanya nedbrytbara metaller är screening av nya material genom in vitro testmetoderett attraktivt alternativ för att undvika onödiga, tidskrävande ochdyrbara djurstudier.Denna avhandling fokuserar på in vitro-testning av zink- och magnesiumbaserademetaller. Inverkan av faktorer såsom sammansättningen av testlösningen,buffersystemet, belastning samt mikrostruktur hos legeringar undersöktes.Genom att använda elektrokemiska in situ tekniker såsom impedansspektroskopi(EIS) är det möjligt att studera gränssnittet mellan metall ochlösning och karakterisera egenskaperna hos den korroderande ytan. Ex situytkaraktäriseringstekniker som svepelektronmikroskopi och infraröd spektroskopianvändes sedan för att komplettera resultaten av de elektrokemiskamätningarna.Korrosionen av zink i Ringer’s lösning fanns vara närmare in vivo korrosionän korrosionen i fosfatbuffrad saltlösning (PBS). Ringers lösning är därför denföredragna testmiljön för långsiktig utvärdering av zinkbaserade metallerDet biologiska buffersystemet (CO2/H2CO3) bör företrädesvis användasför att stabilisera pH-värdet på testlösningen vid magnesiumnedbrytning. NärHEPES användes för att stabilisera pH ökade korrosionshastigheten på grundav bildning av mindre skyddande skikt av korrosionsproduktMöjligheten att använda helblod och plasma som mer kliniskt relevantatestmiljöer utvärderades och befanns producera reproducerbara resultat.Bildning av ett korrosionsskikt bestående av både organiskt och oorganisktmaterial detekterades på zink i både plasma och helblod.När zink prover i helbod utsattes för belastning förhindrade korrosionsskiktetbildningen av mikrosprickor och förtidigt brott av provet. Det varvidare möjligt att detektera tidig sprickbildning på grund av belastning avMagnesium AZ61-legering med EIS.Adsorption av organiska species på zinkytan under anodisk polariseringökar yttäckningen av Zn-joner i helblod. Den ökade yttäckningen leder sedantill utfällningen av ett skyddande skikt av zinkfosfater och en minskadkorrosionshastighet vid högre potentialer.Korrosion av Zn-Mg och Zn-Ag legeringar i Ringers lösning befanns skevia selektiv upplösning. Lokal utfällning av korrosionsprodukter och bildningav ett poröst, mindre skyddande skikt av korrosionsprodukter hittades påZn-Mg legeringar. Den selektiva upplösningen av Zn-Ag legering orsakade enanrikning av AgZn3 vilket kan påverka biokompatibiliteten av ett implantatmed tiden. 
  • Degradable metallic implants are a new class of biomaterials with potentialto replace permanent materials in temporary applications to reduce therisk of long term adverse effects.This thesis focuses on in vitro testing of zinc and magnesium based metals.As new degradable metals are developed screening of new materials within vitro test methods is an attractive option to avoid unnecessary, time consumingand expensive animal studies. The influence of factors such as ioniccomposition of the test solution, buffer system, strain and alloy compositionwas investigated. By employing electrochemical in situ techniques such asimpedance spectroscopy it is possible to study the metal-solution interfaceand determine the properties of the corroding surface. Ex situ surface characterizationtechniques such as scanning electron microscopy and infraredspectroscopy were then used to complement the results of the electrochemicalmeasurements.The importance of appropriate selection of the test solution is highlightedin this work. Zinc was found to corrode in Ringer’s solution by a mechanismcloser to in vivo corrosion than in a phosphate buffered saline solution(PBS).Ringer’s solution is therefore the more appropriate test environment for longterm evaluation of zinc based metals.When evaluating the corrosion of Zn-Mg and Zn-Ag alloys in Ringer’ssolution selective dissolution was found to occur for both types of alloys. Localprecipitation and formation of a porous, less protective, layer of corrosionproducts was found for Zn-Mg alloys. The selective dissolution of Zn-Agalloy caused an enrichment of AgZn3 on the surface which may affect thebiocompatibility of the alloy.The use of HEPES to maintain the pH of the test solution increasedthe corrosion rate of magnesium due to formation of a less protective layerof corrosion products. Magnesium corrosion should therefore preferably bestudied in solutions where the pH is maintained by the biological buffer systemCO2/H2CO3.In addition to saline solutions human whole blood and plasma were evaluatedas more clinically relevant in vitro environments. They were found toproduce reproducible results and to be suitable for short term experiments.Formation of a corrosion product layer comprised of both organic and inorganicmaterial was detected on zinc in both plasma and whole blood.During anodic polarization the adsorption of organic species on the zincsurface was found to increase the surface coverage of Zn ions in whole blood.The increased surface coverage then allowed for precipitation of a protectivelayer of Zn5(PO4)3 and a subsequent decrease in corrosion rate at higherpotentials.When subjecting zinc samples to strain the organic/inorganic corrosionproduct formed in whole blood was observed by impedance spectroscopy toprevent micro cracking and premature failure.The cracking of magnesium alloy samples under applied strain was alsocharacterized by impedance. Changes in surface properties due to crack initiation 

Ämnesord

Engineering and Technology  (hsv)
Industrial Biotechnology  (hsv)
Bio Materials  (hsv)
Teknik och teknologier  (hsv)
Industriell bioteknik  (hsv)
Biomaterial  (hsv)
Materials Engineering  (hsv)
Metallurgy and Metallic Materials  (hsv)
Materialteknik  (hsv)
Metallurgi och metalliska material  (hsv)
Materials Science and Engineering  (kth)
Teknisk materialvetenskap  (kth)

Indexterm och SAB-rubrik

biodegradable
metal
zinc
magnesium
corrosion
electrochemistry
Inställningar Hjälp

Uppgift om bibliotek saknas i LIBRIS

Kontakta ditt bibliotek, eller sök utanför LIBRIS. Se högermenyn.

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy