Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:9qcfbklf7l2rk9j8 > In-vitro and In-Viv...

In-vitro and In-Vivo Assessment of 4D Flow MRI Reynolds Stress Mapping for Pulsatile Blood Flow [Elektronisk resurs]

Ha, Hojin (författare)
Huh, Hyung Kyu (författare)
Park, Kyung Jin (författare)
Dyverfeldt, Petter, 1980- (författare)
Ebbers, Tino (författare)
Kim, Dae-Hee (författare)
Yang, Dong Hyun (författare)
Linköpings universitet Institutionen för hälsa, medicin och vård (utgivare)
Linköpings universitet Medicinska fakulteten (utgivare)
Linköpings universitet Centrum för medicinsk bildvetenskap och visualisering, CMIV (utgivare)
Publicerad: Frontiers Media S.A. 2021
Engelska.
Ingår i: Frontiers in Bioengineering and Biotechnology. ; 9
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Imaging hemodynamics play an important role in the diagnosis of abnormal blood flow due to vascular and valvular diseases as well as in monitoring the recovery of normal blood flow after surgical or interventional treatment. Recently, characterization of turbulent blood flow using 4D flow magnetic resonance imaging (MRI) has been demonstrated by utilizing the changes in signal magnitude depending on intravoxel spin distribution. The imaging sequence was extended with a six-directional icosahedral (ICOSA6) flow-encoding to characterize all elements of the Reynolds stress tensor (RST) in turbulent blood flow. In the present study, we aimed to demonstrate the feasibility of full RST analysis using ICOSA6 4D flow MRI under physiological conditions. First, the turbulence analysis was performed through in vitro experiments with a physiological pulsatile flow condition. Second, a total of 12 normal subjects and one patient with severe aortic stenosis were analyzed using the same sequence. The in-vitro study showed that total turbulent kinetic energy (TKE) was less affected by the signal-to-noise ratio (SNR), however, maximum principal turbulence shear stress (MPTSS) and total turbulence production (TP) had a noise-induced bias. Smaller degree of the bias was observed for TP compared to MPTSS. In-vivo study showed that the subject-variability on turbulence quantification was relatively low for the consistent scan protocol. The in vivo demonstration of the stenosis patient showed that the turbulence analysis could clearly distinguish the difference in all turbulence parameters as they were at least an order of magnitude larger than those from the normal subjects. 

Ämnesord

Engineering and Technology  (hsv)
Mechanical Engineering  (hsv)
Fluid Mechanics and Acoustics  (hsv)
Teknik och teknologier  (hsv)
Maskinteknik  (hsv)
Strömningsmekanik och akustik  (hsv)

Genre

government publication  (marcgt)

Indexterm och SAB-rubrik

magnetic resonace imaging; turbulence measurement; turbulent kinetic energy; turbulence production; hemodynamics
Inställningar Hjälp

Ingår i annan publikation. Gå till titeln Frontiers in Bioengineering and Biotechnology

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy