Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:16222704 > Optical see-through...

Optical see-through head mounted display [Elektronisk resurs] : direct linear transformation calibration robustness in the presence of user alignment noise / Magnus Axholt, Martin Skoglund, Stephen Peterson, Matthew Cooper, Thomas Schön, Fredrik Gustafsson, Anders Ynnerman, Stephen Ellis

Axholt, Magnus, 1978-
Skoglund, Martin, 1981-
Peterson, Stephen 
Cooper, Matthew 
Schön, Thomas 
Gustafsson, Fredrik 
Ynnerman, Anders, 1963-
Ellis, Stephen 
Linköpings universitet. Institutionen för systemteknik (utgivare)
Alternativt namn: ISY
Alternativt namn: Engelska: Linköping University. Department of Electrical Engineering
Linköping : Department of Electrical Engineering, Linköpings universitet, 2010
Engelska 7 s.
Serie: LiTH-ISY-R, 1400-3902 ; 3003
Läs hela texten (Sammanfattning och fulltext från Linköping University Electronic Press)
  • E-bok
Sammanfattning Ämnesord
Stäng  
  • The correct spatial registration between virtual and real objects in optical see-through augmented reality implies accurate estimates of the user’s eyepoint relative to the location and orientation of the display surface. A common approach is to estimate the display parameters through a calibration procedure involving a subjective alignment exercise. Human postural sway and targeting precision contribute to imprecise alignments, which in turn adversely affect the display parameter estimation resulting in registration errors between virtual and real objects. The technique commonly used has its origin incomputer vision, and calibrates stationary cameras using hundreds of correspondence points collected instantaneously in one video frame where precision is limited only by pixel quantization and image blur. Subsequently the input noise level is several order of magnitudes greater when a human operator manually collects correspondence points one by one. This paper investigates the effect of human alignment noise on view parameter estimation in an optical see-through head mounted display to determine how well astandard camera calibration method performs at greater noise levels than documented in computer vision literature. Through Monte-Carlo simulations we show that it is particularly difficult to estimate the user’s eyepoint in depth, but that a greater distribution of correspondence points in depth help mitigate the effects of human alignment noise. 

Indexterm och SAB-rubrik

Head-mounted display ; Calibration ; Direct linear transform ; Robustness
Inställningar Hjälp

Titeln finns på 1 bibliotek. 

Bibliotek i östra Sverige (1)

Ange som favorit
Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy