Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:22115794 > Evaluation of neutr...

Evaluation of neutron spectrometer techniques for ITER using synthetic data [Elektronisk resurs]

Andersson Sundén, Erik (författare)
Ballabio, Luigi (författare)
Cecconello, Marco (författare)
Conroy, Sean (författare)
Ericsson, Göran (författare)
Gatu Johnson, Maria (författare)
Gorini, Giuseppe (författare)
Hellesen, Carl (författare)
Ognissanto, Flora (författare)
Ronchi, Emanuele (författare)
Sjöstrand, Henrik (författare)
Tardocchi, Marco (författare)
Weiszflog, Matthias (författare)
Uppsala universitet Teknisk-naturvetenskapliga vetenskapsområdet (utgivare)
2013
Engelska.
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002. ; 701, 62-71
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • A neutron spectrometer at ITER is expected to provide estimates of plasma parameters such as ion temperature, T i , fuel ion ratio, n t / n d , and Q thermal /Q tot , with 10-20% precision at a time resolution, Δt , of at least 100 ms. The present paper describes a method for evaluating different neutron spectroscopy techniques based on their instrumental response functions and synthetic measurement data. We include five different neutron spectrometric techniques with realistic response functions, based on simulations and measurements where available. The techniques are magnetic proton recoil, thin-foil proton recoil, gamma discriminating organic scintillator, diamond and time-of-flight. The reference position and line of sight of a high resolution neutron spectrometer on ITER are used in the study. ITER plasma conditions are simulated for realistic operating scenarios. The ITER conditions evaluated are beam and radio frequency heated and thermal deuterium-tritium plasmas. Results are given for each technique in terms of the estimated time resolution at which the parameter determination can be made within the required precision (here 10% for T i and the relative intensities of NB and RF emission components). It is shown that under the assumptions made, the thin-foil techniques out-perform the other spectroscopy techniques in practically all measurement situations. For thermal conditions, the range of achieved Δt in the determination of T i varies in time scales from ms (for the magnetic and thin-foil proton recoil) to s (for gamma discriminating organic scintillator). 

Ämnesord

Natural Sciences  (hsv)
Physical Sciences  (hsv)
Naturvetenskap  (hsv)
Fysik  (hsv)
NATURAL SCIENCES  (svep)
Physics  (svep)
NATURVETENSKAP  (svep)
Fysik  (svep)
Inställningar Hjälp

Beståndsinformation saknas

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy