Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:21777677 > Image Analysis for ...

Image Analysis for Trabecular Bone Properties on Cone-Beam CT Data [Elektronisk resurs] / Eva Klintström

Klintström, Eva 1957- (författare)
Smedby, Örjan 1956- (preses)
Moren, Rodrigo (preses)
Brismar, Torkel (preses)
Mellström, Dan (opponent)
Linköpings universitet Centrum för medicinsk bildvetenskap och visualisering, CMIV (utgivare)
Linköpings universitet Institutionen för medicin och hälsa (utgivare)
Alternativt namn: IMH
Alternativt namn: Engelska: Linköping Universty. Department of Medical and Health Sciences
Alternativt namn: Linköping Universty. Department of Medicine and Health Sciences
Se även: Linköpings universitet. Institutionen för hälsa och samhälle
Se även: Linköpings universitet. Institutionen för medicin och vård
Linköpings universitet Medicinska fakulteten (utgivare)
Linköping Department of Medical and Health Sciences, Linköping University, 2017
Engelska 71 s. (PDF)
Serie: Linköping University Medical Dissertations 0345-0082 ; 1594
Läs hela texten
Läs hela texten (Sammanfattning och ramberättelse från Linköping University Electronic Press)
Läs hela texten
  • E-bokAvhandling(Diss. (sammanfattning) Linköping : Linköpings universitet, 2017)
Sammanfattning Ämnesord
Stäng  
  • Trabecular bone structure as well as bone mineral density (BMD) have impact on the biomechanical competence of bone. In osteoporosis-related fractures, there have been shown to exist disconnections in the trabecular network as well as low bone mineral density. Imaging of bone parameters is therefore of importance in detecting osteoporosis. One available imaging device is cone-beam computed tomography (CBCT). This device is often used in pre-operative imaging of dental implants, for which the trabecular network also has great importance. Fourteen or 15 trabecular bone specimens from the radius were imaged for conducting this in vitro project. The imaging data from one dual-energy X-ray absorptiometry (DXA), two multi-slice computed tomography (MSCT), one high-resolution peripheral quantitative computed tomography (HR-pQCT) and four CBCT devices were segmented using an in-house developed code based on homogeneity thresholding. Seven trabecular microarchitecture parameters, as well as two trabecular bone stiffness parameters, were computed from the segmented data. Measurements from micro-computed tomography (micro-CT) data of the same bone specimens were regarded as gold standard. Correlations between MSCT and micro-CT data showed great variations, depending on device, imaging parameters and between the bone parameters. Only the bone-volume fraction (BV/TV) parameter was stable with strong correlations. Regarding both HR-pQCT and CBCT, the correlations to micro-CT were strong for bone structure parameters as well as bone stiffness parameters. The CBCT device 3D Accuitomo showed the strongest correlations, but overestimated BV/TV more than three times compared to micro-CT. The imaging protocol most often used in clinical imaging practice at our clinic demonstrated strong correlations as well as low radiation dose. CBCT data of trabecular bone can be used for analysing trabecular bone properties, like bone microstructure and bone biomechanics, showing strong correlations to the reference method of micro-CT. The results depend on choice of CBCT device as well as segmentation method used. The in-house developed code based on homogeneity thresholding is appropriate for CBCT data. The overestimations of BV/TV must be considered when estimating bone properties in future clinical dental implant and osteoporosis research. 

Ämnesord

Bone Density  (MeSH)
Cancellous Bone  (MeSH)
Cone-Beam Computed Tomography  (MeSH)
Engineering and Technology  (hsv)
Medical Engineering  (hsv)
Medical Image Processing  (hsv)
Teknik och teknologier  (hsv)
Medicinteknik  (hsv)
Medicinsk bildbehandling  (hsv)

Klassifikation

611.71 (DDC)
J.08 (kssb/8 (machine generated))
Inställningar Hjälp

Titeln finns på 1 bibliotek. 

Bibliotek i östra Sverige (1)

Ange som favorit
Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy